iio: mcp4531: provide range of available raw values

Example:

$ cat '/sys/bus/iio/devices/iio:device0/out_resistance_raw_available'
[0 1 256]

Meaning: min 0, step 1 and max 256.

Signed-off-by: Peter Rosin <[email protected]>
Signed-off-by: Jonathan Cameron <[email protected]>
3 files changed