bms: update power_supply enums
rename POWER_SUPPLY_CHARGE_TYPE_EXT to POWER_SUPPLY_CHARGE_TYPE
Bug: 203233222
Signed-off-by: Jack Wu <[email protected]>
Change-Id: I0b0b4e133a1c4ff804e32b40535d82eaa1ffac35
diff --git a/google_battery.c b/google_battery.c
index 5693ffd..b7b55d6 100644
--- a/google_battery.c
+++ b/google_battery.c
@@ -2213,7 +2213,7 @@
batt_prlog(BATT_PRLOG_ALWAYS, "MSC_PRE vt=%d vb=%d fv_uv=%d chg_type=%d\n",
vtier, vbatt, *fv_uv, chg_type);
- } else if (chg_type != POWER_SUPPLY_CHARGE_TYPE_TAPER_EXT) {
+ } else if (chg_type != POWER_SUPPLY_CHARGE_TYPE_TAPER) {
const int type_margin = utv_margin;
/*
@@ -2694,7 +2694,7 @@
if (chg_type == POWER_SUPPLY_CHARGE_TYPE_FAST) {
msc_state = MSC_FAST;
- } else if (chg_type != POWER_SUPPLY_CHARGE_TYPE_TAPER_EXT) {
+ } else if (chg_type != POWER_SUPPLY_CHARGE_TYPE_TAPER) {
msc_state = MSC_TYPE;
} else {
msc_state = MSC_LAST;