commit | 823ed102669618894cd48b806264d3b64462db85 | [log] [tgz] |
---|---|---|
author | Wasb Liu <[email protected]> | Tue Oct 26 17:09:22 2021 +0800 |
committer | Wasb Liu <[email protected]> | Wed Oct 27 03:11:09 2021 +0000 |
tree | 7ef6bf86fa2535134190c037e447fc62858b98ee | |
parent | 7376b72f150919c2fe1311c52abc0688f833ddfc [diff] |
max77759_charger: add THM2 monitoring feature This feature is enabled by "google,max77759-thm2-monitor". When THM2 reaches 60 degreeC, device will stop charging; when THM2 cools down, device will auto recover charging. Bug: 198385161 Signed-off-by: Wasb Liu <[email protected]> Change-Id: If94eb0bd106152ddfc4bf35a8cafedf1008a8bd7