| Analog Devices ADIS16480 and similar IMUs |
| |
| Required properties for the ADIS16480: |
| |
| - compatible: Must be one of |
| * "adi,adis16375" |
| * "adi,adis16480" |
| * "adi,adis16485" |
| * "adi,adis16488" |
| * "adi,adis16490" |
| * "adi,adis16495-1" |
| * "adi,adis16495-2" |
| * "adi,adis16495-3" |
| * "adi,adis16497-1" |
| * "adi,adis16497-2" |
| * "adi,adis16497-3" |
| - reg: SPI chip select number for the device |
| - spi-max-frequency: Max SPI frequency to use |
| see: Documentation/devicetree/bindings/spi/spi-bus.txt |
| - spi-cpha: See Documentation/devicetree/bindings/spi/spi-bus.txt |
| - spi-cpol: See Documentation/devicetree/bindings/spi/spi-bus.txt |
| - interrupts: interrupt mapping for IRQ, accepted values are: |
| * IRQF_TRIGGER_RISING |
| * IRQF_TRIGGER_FALLING |
| |
| Optional properties: |
| |
| - interrupt-names: Data ready line selection. Valid values are: |
| * DIO1 |
| * DIO2 |
| * DIO3 |
| * DIO4 |
| If this field is left empty, DIO1 is assigned as default data ready |
| signal. |
| - reset-gpios: must be the device tree identifier of the RESET pin. As the line |
| is active low, it should be marked GPIO_ACTIVE_LOW. |
| - clocks: phandle to the external clock. Should be set according to |
| "clock-names". |
| If this field is left empty together with the "clock-names" field, then |
| the internal clock is used. |
| - clock-names: The name of the external clock to be used. Valid values are: |
| * sync: In sync mode, the internal clock is disabled and the frequency |
| of the external clock signal establishes therate of data |
| collection and processing. See Fig 14 and 15 in the datasheet. |
| The clock-frequency must be: |
| * 3000 to 4500 Hz for adis1649x devices. |
| * 700 to 2400 Hz for adis1648x devices. |
| * pps: In Pulse Per Second (PPS) Mode, the rate of data collection and |
| production is equal to the product of the external clock |
| frequency and the scale factor in the SYNC_SCALE register, see |
| Table 154 in the datasheet. |
| The clock-frequency must be: |
| * 1 to 128 Hz for adis1649x devices. |
| * This mode is not supported by adis1648x devices. |
| If this field is left empty together with the "clocks" field, then the |
| internal clock is used. |
| - adi,ext-clk-pin: The DIOx line to be used as an external clock input. |
| Valid values are: |
| * DIO1 |
| * DIO2 |
| * DIO3 |
| * DIO4 |
| Each DIOx pin supports only one function at a time (data ready line |
| selection or external clock input). When a single pin has two |
| two assignments, the enable bit for the lower priority function |
| automatically resets to zero (disabling the lower priority function). |
| Data ready has highest priority. |
| If this field is left empty, DIO2 is assigned as default external clock |
| input pin. |
| |
| Example: |
| |
| imu@0 { |
| compatible = "adi,adis16495-1"; |
| reg = <0>; |
| spi-max-frequency = <3200000>; |
| spi-cpol; |
| spi-cpha; |
| interrupts = <25 IRQF_TRIGGER_FALLING>; |
| interrupt-parent = <&gpio>; |
| interrupt-names = "DIO2"; |
| clocks = <&adis16495_sync>; |
| clock-names = "sync"; |
| adi,ext-clk-pin = "DIO1"; |
| }; |