|  | Generic Thermal Sysfs driver How To | 
|  | ========================= | 
|  |  | 
|  | Written by Sujith Thomas <[email protected]>, Zhang Rui <[email protected]> | 
|  |  | 
|  | Updated: 2 January 2008 | 
|  |  | 
|  | Copyright (c)  2008 Intel Corporation | 
|  |  | 
|  |  | 
|  | 0. Introduction | 
|  |  | 
|  | The generic thermal sysfs provides a set of interfaces for thermal zone devices (sensors) | 
|  | and thermal cooling devices (fan, processor...) to register with the thermal management | 
|  | solution and to be a part of it. | 
|  |  | 
|  | This how-to focuses on enabling new thermal zone and cooling devices to participate | 
|  | in thermal management. | 
|  | This solution is platform independent and any type of thermal zone devices and | 
|  | cooling devices should be able to make use of the infrastructure. | 
|  |  | 
|  | The main task of the thermal sysfs driver is to expose thermal zone attributes as well | 
|  | as cooling device attributes to the user space. | 
|  | An intelligent thermal management application can make decisions based on inputs | 
|  | from thermal zone attributes (the current temperature and trip point temperature) | 
|  | and throttle appropriate devices. | 
|  |  | 
|  | [0-*]	denotes any positive number starting from 0 | 
|  | [1-*]	denotes any positive number starting from 1 | 
|  |  | 
|  | 1. thermal sysfs driver interface functions | 
|  |  | 
|  | 1.1 thermal zone device interface | 
|  | 1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *name, int trips, | 
|  | void *devdata, struct thermal_zone_device_ops *ops) | 
|  |  | 
|  | This interface function adds a new thermal zone device (sensor) to | 
|  | /sys/class/thermal folder as thermal_zone[0-*]. | 
|  | It tries to bind all the thermal cooling devices registered at the same time. | 
|  |  | 
|  | name: the thermal zone name. | 
|  | trips: the total number of trip points this thermal zone supports. | 
|  | devdata: device private data | 
|  | ops: thermal zone device call-backs. | 
|  | .bind: bind the thermal zone device with a thermal cooling device. | 
|  | .unbind: unbind the thermal zone device with a thermal cooling device. | 
|  | .get_temp: get the current temperature of the thermal zone. | 
|  | .get_mode: get the current mode (user/kernel) of the thermal zone. | 
|  | "kernel" means thermal management is done in kernel. | 
|  | "user" will prevent kernel thermal driver actions upon trip points | 
|  | so that user applications can take charge of thermal management. | 
|  | .set_mode: set the mode (user/kernel) of the thermal zone. | 
|  | .get_trip_type: get the type of certain trip point. | 
|  | .get_trip_temp: get the temperature above which the certain trip point | 
|  | will be fired. | 
|  |  | 
|  | 1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz) | 
|  |  | 
|  | This interface function removes the thermal zone device. | 
|  | It deletes the corresponding entry form /sys/class/thermal folder and unbind all | 
|  | the thermal cooling devices it uses. | 
|  |  | 
|  | 1.2 thermal cooling device interface | 
|  | 1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name, | 
|  | void *devdata, struct thermal_cooling_device_ops *) | 
|  |  | 
|  | This interface function adds a new thermal cooling device (fan/processor/...) to | 
|  | /sys/class/thermal/ folder as cooling_device[0-*]. | 
|  | It tries to bind itself to all the thermal zone devices register at the same time. | 
|  | name: the cooling device name. | 
|  | devdata: device private data. | 
|  | ops: thermal cooling devices call-backs. | 
|  | .get_max_state: get the Maximum throttle state of the cooling device. | 
|  | .get_cur_state: get the Current throttle state of the cooling device. | 
|  | .set_cur_state: set the Current throttle state of the cooling device. | 
|  |  | 
|  | 1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev) | 
|  |  | 
|  | This interface function remove the thermal cooling device. | 
|  | It deletes the corresponding entry form /sys/class/thermal folder and unbind | 
|  | itself from all	the thermal zone devices using it. | 
|  |  | 
|  | 1.3 interface for binding a thermal zone device with a thermal cooling device | 
|  | 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz, | 
|  | int trip, struct thermal_cooling_device *cdev); | 
|  |  | 
|  | This interface function bind a thermal cooling device to the certain trip point | 
|  | of a thermal zone device. | 
|  | This function is usually called in the thermal zone device .bind callback. | 
|  | tz: the thermal zone device | 
|  | cdev: thermal cooling device | 
|  | trip: indicates which trip point the cooling devices is associated with | 
|  | in this thermal zone. | 
|  |  | 
|  | 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz, | 
|  | int trip, struct thermal_cooling_device *cdev); | 
|  |  | 
|  | This interface function unbind a thermal cooling device from the certain trip point | 
|  | of a thermal zone device. | 
|  | This function is usually called in the thermal zone device .unbind callback. | 
|  | tz: the thermal zone device | 
|  | cdev: thermal cooling device | 
|  | trip: indicates which trip point the cooling devices is associated with | 
|  | in this thermal zone. | 
|  |  | 
|  | 2. sysfs attributes structure | 
|  |  | 
|  | RO	read only value | 
|  | RW	read/write value | 
|  |  | 
|  | All thermal sysfs attributes will be represented under /sys/class/thermal | 
|  |  | 
|  | Thermal zone device sys I/F, created once it's registered: | 
|  | |thermal_zone[0-*]: | 
|  | |-----type:			Type of the thermal zone | 
|  | |-----temp:			Current temperature | 
|  | |-----mode:			Working mode of the thermal zone | 
|  | |-----trip_point_[0-*]_temp:	Trip point temperature | 
|  | |-----trip_point_[0-*]_type:	Trip point type | 
|  |  | 
|  | Thermal cooling device sys I/F, created once it's registered: | 
|  | |cooling_device[0-*]: | 
|  | |-----type :			Type of the cooling device(processor/fan/...) | 
|  | |-----max_state:		Maximum cooling state of the cooling device | 
|  | |-----cur_state:		Current cooling state of the cooling device | 
|  |  | 
|  |  | 
|  | These two dynamic attributes are created/removed in pairs. | 
|  | They represent the relationship between a thermal zone and its associated cooling device. | 
|  | They are created/removed for each | 
|  | thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device successful execution. | 
|  |  | 
|  | |thermal_zone[0-*] | 
|  | |-----cdev[0-*]:		The [0-*]th cooling device in the current thermal zone | 
|  | |-----cdev[0-*]_trip_point:	Trip point that cdev[0-*] is associated with | 
|  |  | 
|  |  | 
|  | *************************** | 
|  | * Thermal zone attributes * | 
|  | *************************** | 
|  |  | 
|  | type				Strings which represent the thermal zone type. | 
|  | This is given by thermal zone driver as part of registration. | 
|  | Eg: "ACPI thermal zone" indicates it's a ACPI thermal device | 
|  | RO | 
|  | Optional | 
|  |  | 
|  | temp				Current temperature as reported by thermal zone (sensor) | 
|  | Unit: degree Celsius | 
|  | RO | 
|  | Required | 
|  |  | 
|  | mode				One of the predefined values in [kernel, user] | 
|  | This file gives information about the algorithm | 
|  | that is currently managing the thermal zone. | 
|  | It can be either default kernel based algorithm | 
|  | or user space application. | 
|  | RW | 
|  | Optional | 
|  | kernel	= Thermal management in kernel thermal zone driver. | 
|  | user	= Preventing kernel thermal zone driver actions upon | 
|  | trip points so that user application can take full | 
|  | charge of the thermal management. | 
|  |  | 
|  | trip_point_[0-*]_temp		The temperature above which trip point will be fired | 
|  | Unit: degree Celsius | 
|  | RO | 
|  | Optional | 
|  |  | 
|  | trip_point_[0-*]_type 		Strings which indicate the type of the trip point | 
|  | E.g. it can be one of critical, hot, passive, | 
|  | active[0-*] for ACPI thermal zone. | 
|  | RO | 
|  | Optional | 
|  |  | 
|  | cdev[0-*]			Sysfs link to the thermal cooling device node where the sys I/F | 
|  | for cooling device throttling control represents. | 
|  | RO | 
|  | Optional | 
|  |  | 
|  | cdev[0-*]_trip_point		The trip point with which cdev[0-*] is associated in this thermal zone | 
|  | -1 means the cooling device is not associated with any trip point. | 
|  | RO | 
|  | Optional | 
|  |  | 
|  | ****************************** | 
|  | * Cooling device  attributes * | 
|  | ****************************** | 
|  |  | 
|  | type				String which represents the type of device | 
|  | eg: For generic ACPI: this should be "Fan", | 
|  | "Processor" or "LCD" | 
|  | eg. For memory controller device on intel_menlow platform: | 
|  | this should be "Memory controller" | 
|  | RO | 
|  | Optional | 
|  |  | 
|  | max_state			The maximum permissible cooling state of this cooling device. | 
|  | RO | 
|  | Required | 
|  |  | 
|  | cur_state			The current cooling state of this cooling device. | 
|  | the value can any integer numbers between 0 and max_state, | 
|  | cur_state == 0 means no cooling | 
|  | cur_state == max_state means the maximum cooling. | 
|  | RW | 
|  | Required | 
|  |  | 
|  | 3. A simple implementation | 
|  |  | 
|  | ACPI thermal zone may support multiple trip points like critical/hot/passive/active. | 
|  | If an ACPI thermal zone supports critical, passive, active[0] and active[1] at the same time, | 
|  | it may register itself as a thermal_zone_device (thermal_zone1) with 4 trip points in all. | 
|  | It has one processor and one fan, which are both registered as thermal_cooling_device. | 
|  | If the processor is listed in _PSL method, and the fan is listed in _AL0 method, | 
|  | the sys I/F structure will be built like this: | 
|  |  | 
|  | /sys/class/thermal: | 
|  |  | 
|  | |thermal_zone1: | 
|  | |-----type:			ACPI thermal zone | 
|  | |-----temp:			37 | 
|  | |-----mode:			kernel | 
|  | |-----trip_point_0_temp:	100 | 
|  | |-----trip_point_0_type:	critical | 
|  | |-----trip_point_1_temp:	80 | 
|  | |-----trip_point_1_type:	passive | 
|  | |-----trip_point_2_temp:	70 | 
|  | |-----trip_point_2_type:	active[0] | 
|  | |-----trip_point_3_temp:	60 | 
|  | |-----trip_point_3_type:	active[1] | 
|  | |-----cdev0:			--->/sys/class/thermal/cooling_device0 | 
|  | |-----cdev0_trip_point:		1	/* cdev0 can be used for passive */ | 
|  | |-----cdev1:			--->/sys/class/thermal/cooling_device3 | 
|  | |-----cdev1_trip_point:		2	/* cdev1 can be used for active[0]*/ | 
|  |  | 
|  | |cooling_device0: | 
|  | |-----type:			Processor | 
|  | |-----max_state:		8 | 
|  | |-----cur_state:		0 | 
|  |  | 
|  | |cooling_device3: | 
|  | |-----type:			Fan | 
|  | |-----max_state:		2 | 
|  | |-----cur_state:		0 |