| # Copyright 2017 The Chromium OS Authors. All rights reserved. |
| # Use of this source code is governed by a BSD-style license that can be |
| # found in the LICENSE file. |
| |
| import logging |
| |
| from autotest_lib.client.common_lib import error |
| from autotest_lib.client.common_lib.cros import cr50_utils, tpm_utils |
| from autotest_lib.server.cros.faft.cr50_test import Cr50Test |
| |
| |
| class firmware_Cr50SetBoardId(Cr50Test): |
| """Verify cr50-set-board-id.sh |
| |
| Verify cr50-set-board-id sets the correct board id and flags based on the |
| given stage. |
| """ |
| version = 1 |
| |
| BID_SCRIPT = '/usr/share/cros/cr50-set-board-id.sh' |
| |
| # the command to get the brand name |
| GET_BRAND = 'mosys platform brand' |
| |
| # Used when the flags were not initialized in the factory. |
| UNKNOWN_FLAGS = 0xff00 |
| # Used for dev, proto, EVT, and DVT phases. |
| DEVELOPMENT_FLAGS = 0xff7f |
| # Used for PVT and MP builds. |
| RELEASE_FLAGS = 0x7f80 |
| PHASE_FLAGS_DICT = { |
| 'unknown' : UNKNOWN_FLAGS, |
| |
| 'dev' : DEVELOPMENT_FLAGS, |
| 'proto' : DEVELOPMENT_FLAGS, |
| 'evt' : DEVELOPMENT_FLAGS, |
| 'dvt' : DEVELOPMENT_FLAGS, |
| |
| 'mp' : RELEASE_FLAGS, |
| 'pvt' : RELEASE_FLAGS, |
| } |
| |
| # The response strings from cr50-set-board-id |
| SUCCESS = ["Successfully updated board ID to 'BID' with phase 'PHASE'.", |
| 0] |
| ERROR_UNKNOWN_PHASE = ['Unknown phase (PHASE)', 1] |
| ERROR_INVALID_RLZ = ['Invalid RLZ brand code (BID).', 1] |
| ERROR_ALREADY_SET = ['Board ID and flag have already been set.', 2] |
| ERROR_BID_SET_DIFFERENTLY = ['Board ID has been set differently.', 3] |
| ERROR_FLAG_SET_DIFFERENTLY = ['Flag has been set differently.', 3] |
| |
| def initialize(self, host, cmdline_args, dev_path='', bid=''): |
| # Restore the original image, rlz code, and board id during cleanup. |
| super(firmware_Cr50SetBoardId, self).initialize(host, cmdline_args, |
| restore_cr50_state=True, cr50_dev_path=dev_path) |
| if self.cr50.using_ccd(): |
| raise error.TestNAError('Use a flex cable instead of CCD cable.') |
| |
| # Update to the dev image so we can erase the board id after we set it. |
| # This test is verifying cr50-set-board-id and not the actual getting/ |
| # setting of the board id on the cr50 side, so it is ok if the cr50 is |
| # running a dev image. |
| self.cr50_update(self.get_saved_cr50_dev_path()) |
| |
| if not self.cr50.has_command('bid'): |
| raise error.TestNAError('Cr50 image does not support board id') |
| |
| if not self.host.path_exists(self.BID_SCRIPT): |
| raise error.TestNAError('Device does not have "cr50-set-board-id"') |
| |
| result = self.host.run(self.GET_BRAND, ignore_status=True) |
| platform_brand = result.stdout.strip() |
| if result.exit_status or not platform_brand: |
| raise error.TestNAError('Could not get "mosys platform brand"') |
| self.platform_brand = platform_brand |
| self.erase_bid() |
| cr50_utils.StopTrunksd(self.host) |
| |
| |
| def cleanup(self): |
| """Clear the TPM Owner""" |
| super(firmware_Cr50SetBoardId, self).cleanup() |
| tpm_utils.ClearTPMOwnerRequest(self.host) |
| |
| |
| def erase_bid(self): |
| """Erase the current board id""" |
| self.cr50.send_command('eraseflashinfo') |
| |
| |
| def run_script(self, expected_result, phase, board_id=''): |
| """Run the bid script with the given phase and board id |
| |
| Args: |
| expected_result: a list with the result message and exit status |
| phase: The phase string. |
| board_id: The board id string. |
| |
| Raises: |
| TestFail if the expected result message did not match the script |
| output |
| """ |
| message, exit_status = expected_result |
| |
| # If we expect an error ignore the exit status |
| ignore_status = not not exit_status |
| |
| # Run the script with the phase and board id |
| cmd = '%s %s %s' % (self.BID_SCRIPT, phase, board_id) |
| result = self.host.run(cmd, ignore_status=ignore_status) |
| |
| # If we don't give the script a board id, it will use the platform |
| # brand |
| expected_board_id = board_id if board_id else self.platform_brand |
| # Replace the placeholders with the expected board id and phase |
| message = message.replace('BID', expected_board_id) |
| message = message.replace('PHASE', phase) |
| |
| # Compare the expected script output to the actual script result |
| if message not in result.stdout or exit_status != result.exit_status: |
| logging.debug(result) |
| raise error.TestFail('Expected "%s" got "%s"' % (message, |
| result.stdout)) |
| logging.info(result.stdout) |
| |
| |
| def run_once(self): |
| """Verify cr50-set-board-id.sh""" |
| # 'A' is too short to be a valid rlz code |
| self.run_script(self.ERROR_INVALID_RLZ, 'dvt', 'A') |
| # dummy_phase is not a valid phase |
| self.run_script(self.ERROR_UNKNOWN_PHASE, 'dummy_phase') |
| # The rlz code is checked before the phase |
| self.run_script(self.ERROR_INVALID_RLZ, 'dummy_phase', 'A') |
| |
| # Set the board id so we can verify cr50-set-board-id has the correct |
| # response to the board id already being set. |
| self.run_script(self.SUCCESS, 'dvt', 'TEST') |
| # mp has different flags than dvt |
| self.run_script(self.ERROR_FLAG_SET_DIFFERENTLY, 'mp', 'TEST') |
| # try setting the dvt flags with a different board id |
| self.run_script(self.ERROR_BID_SET_DIFFERENTLY, 'dvt', 'test') |
| # running with the same phase and board id will raise an error that the |
| # board id is already set |
| self.run_script(self.ERROR_ALREADY_SET, 'dvt', 'TEST') |
| |
| # Verify each stage sets the right flags |
| for phase, flags in self.PHASE_FLAGS_DICT.iteritems(): |
| # Erase the board id so we can change it. |
| self.erase_bid() |
| |
| # Run the script to set the board id and flags for the given phase. |
| self.run_script(self.SUCCESS, phase) |
| |
| # Check that the board id and flags are actually set. |
| cr50_utils.CheckChipBoardId(self.host, self.platform_brand, flags) |