| # Copyright 2020 The Chromium OS Authors. All rights reserved. |
| # Use of this source code is governed by a BSD-style license that can be |
| # found in the LICENSE file. |
| |
| import logging |
| import time |
| |
| from autotest_lib.client.common_lib import error |
| from autotest_lib.server.cros.faft.firmware_test import FirmwareTest |
| |
| |
| class firmware_ECChargingState(FirmwareTest): |
| """ |
| Type-C servo-v4 based EC charging state test. |
| """ |
| version = 1 |
| |
| # The delay to wait for the AC state to update. |
| AC_STATE_UPDATE_DELAY = 3 |
| |
| # We wait for up to 3 hrs for the battery to report fully charged. |
| FULL_CHARGE_TIMEOUT = 60 * 60 * 3 |
| |
| # The period to check battery state while charging. |
| CHECK_BATT_STATE_WAIT = 60 |
| |
| def initialize(self, host, cmdline_args): |
| super(firmware_ECChargingState, self).initialize(host, cmdline_args) |
| if not self.check_ec_capability(['battery', 'charging']): |
| raise error.TestNAError("Nothing needs to be tested on this DUT") |
| if self.servo.get_servo_version() != 'servo_v4_with_ccd_cr50': |
| raise error.TestNAError("This test can only be run with servo-v4 " |
| "+ CCD. If you don't have a Type-C servo-v4, please run " |
| "the test manually.") |
| if host.is_ac_connected() != True: |
| raise error.TestFail("This test must be run with AC power.") |
| self.switcher.setup_mode('normal') |
| self.ec.send_command("chan save") |
| self.ec.send_command("chan 0") |
| self.set_dut_low_power_idle_delay(20) |
| |
| def cleanup(self): |
| try: |
| self.ec.send_command("chan restore") |
| self.restore_dut_low_power_idle_delay() |
| except Exception as e: |
| logging.error("Caught exception: %s", str(e)) |
| super(firmware_ECChargingState, self).cleanup() |
| |
| def check_ac_state(self): |
| """Check if AC is plugged.""" |
| ac_state = int(self.ec.send_command_get_output("chgstate", |
| ["ac\s*=\s*(0|1)\s*"])[0][1]) |
| if ac_state == 1: |
| return 'on' |
| elif ac_state == 0: |
| return 'off' |
| else: |
| return 'unknown' |
| |
| def get_battery_level(self): |
| """Get battery charge percentage.""" |
| batt_level = int(self.ec.send_command_get_output("battery", |
| ["Charge:\s+(\d+)\s+"])[0][1]) |
| return batt_level |
| |
| def run_once(self, host): |
| """Execute the main body of the test.""" |
| |
| if host.is_ac_connected() != True: |
| raise error.TestFail("This test must be run with AC power.") |
| |
| logging.info("Suspend, unplug AC, and then wake up the device.") |
| self.suspend() |
| self.switcher.wait_for_client_offline() |
| |
| # Call set_servo_v4_role_to_snk() instead of directly setting |
| # servo_v4 role to snk, so servo_v4_role can be recovered to |
| # default src in cleanup(). |
| self.set_servo_v4_role_to_snk() |
| time.sleep(self.AC_STATE_UPDATE_DELAY) |
| |
| # Verify servo v4 is sinking power. |
| if self.check_ac_state() != 'off': |
| raise error.TestFail("Fail to unplug AC.") |
| |
| self.servo.power_normal_press() |
| self.switcher.wait_for_client() |
| |
| batt_state = host.get_battery_state() |
| if batt_state != 'Discharging': |
| raise error.TestFail("Wrong battery state. Expected: " |
| "Discharging, got: %s." % batt_state) |
| |
| logging.info("Suspend, plug AC, and then wake up the device.") |
| self.suspend() |
| self.switcher.wait_for_client_offline() |
| self.servo.set_servo_v4_role('src') |
| time.sleep(self.AC_STATE_UPDATE_DELAY) |
| |
| # Verify servo v4 is sourcing power. |
| if self.check_ac_state() != 'on': |
| raise error.TestFail("Fail to plug AC.") |
| |
| self.servo.power_normal_press() |
| self.switcher.wait_for_client() |
| |
| batt_state = host.get_battery_state() |
| if batt_state != 'Charging' and batt_state != 'Fully charged': |
| raise error.TestFail("Wrong battery state. Expected: " |
| "Charging/Fully charged, got: %s." % batt_state) |
| |
| logging.info("Keep charging until the battery reports fully charged.") |
| deadline = time.time() + self.FULL_CHARGE_TIMEOUT |
| while time.time() < deadline: |
| batt_state = host.get_battery_state() |
| if batt_state == 'Fully charged': |
| logging.info("The battery reports fully charged.") |
| return |
| elif batt_state == 'Charging': |
| logging.info("Wait for the battery to be fully charged. " |
| "The current battery level is %d%%.", |
| self.get_battery_level()) |
| else: |
| raise error.TestFail("The battery state is %s. " |
| "Is AC unplugged?", batt_state) |
| time.sleep(self.CHECK_BATT_STATE_WAIT) |
| |
| raise error.TestFail("The battery does not report fully charged " |
| "before timeout is reached. The final battery level is %d%%.", |
| self.get_battery_level()) |