| .TH setpci 8 "@TODAY@" "@VERSION@" "The PCI Utilities" |
| .SH NAME |
| setpci \- configure PCI devices |
| .SH SYNOPSIS |
| .B setpci |
| .RB [ options ] |
| .B devices |
| .BR operations ... |
| |
| .SH DESCRIPTION |
| .PP |
| .B setpci |
| is a utility for querying and configuring PCI devices. |
| |
| All numbers are entered in hexadecimal notation. |
| |
| Root privileges are necessary for almost all operations, excluding reads |
| of the standard header of the configuration space on some operating systems. |
| Please see |
| .BR lspci(8) |
| for details on access rights. |
| |
| .SH OPTIONS |
| |
| .SS General options |
| .TP |
| .B -v |
| Tells |
| .I setpci |
| to be verbose and display detailed information about configuration space accesses. |
| .TP |
| .B -f |
| Tells |
| .I setpci |
| not to complain when there's nothing to do (when no devices are selected). |
| This option is intended for use in widely-distributed configuration scripts |
| where it's uncertain whether the device in question is present in the machine |
| or not. |
| .TP |
| .B -D |
| `Demo mode' -- don't write anything to the configuration registers. |
| It's useful to try |
| .B setpci -vD |
| to verify that your complex sequence of |
| .B setpci |
| operations does what you think it should do. |
| .TP |
| .B -r |
| Avoids bus scan if each operation selects a specific device (uses the |
| .B -s |
| selector with specific domain, bus, slot, and function). This is faster, |
| but if the device does not exist, it fails instead of matching an empty |
| set of devices. |
| .TP |
| .B --version |
| Show |
| .I setpci |
| version. This option should be used stand-alone. |
| .TP |
| .B --help |
| Show detailed help on available options. This option should be used stand-alone. |
| .TP |
| .B --dumpregs |
| Show a list of all known PCI registers and capabilities. This option should be |
| used stand-alone. |
| |
| .SS PCI access options |
| .PP |
| The PCI utilities use the PCI library to talk to PCI devices (see |
| \fBpcilib\fP(7) for details). You can use the following options to |
| influence its behavior: |
| .TP |
| .B -A <method> |
| The library supports a variety of methods to access the PCI hardware. |
| By default, it uses the first access method available, but you can use |
| this option to override this decision. See \fB-A help\fP for a list of |
| available methods and their descriptions. |
| .TP |
| .B -O <param>=<value> |
| The behavior of the library is controlled by several named parameters. |
| This option allows one to set the value of any of the parameters. Use \fB-O help\fP |
| for a list of known parameters and their default values. |
| .TP |
| .B -H1 |
| Use direct hardware access via Intel configuration mechanism 1. |
| (This is a shorthand for \fB-A intel-conf1\fP.) |
| .TP |
| .B -H2 |
| Use direct hardware access via Intel configuration mechanism 2. |
| (This is a shorthand for \fB-A intel-conf2\fP.) |
| .TP |
| .B -G |
| Increase debug level of the library. |
| |
| .SH DEVICE SELECTION |
| .PP |
| Before each sequence of operations you need to select which devices you wish that |
| operation to affect. |
| .TP |
| .B -s [[[[<domain>]:]<bus>]:][<slot>][.[<func>]] |
| Consider only devices in the specified domain (in case your machine has several host bridges, |
| they can either share a common bus number space or each of them can address a PCI domain |
| of its own; domains are numbered from 0 to ffff), bus (0 to ff), slot (0 to 1f) and function (0 to 7). |
| Each component of the device address can be omitted or set to "*", both meaning "any value". All numbers are |
| hexadecimal. E.g., "0:" means all devices on bus 0, "0" means all functions of device 0 |
| on any bus, "0.3" selects third function of device 0 on all buses and ".4" matches only |
| the fourth function of each device. |
| .TP |
| .B -d [<vendor>]:[<device>][:<class>[:<prog-if>]] |
| Select devices with specified vendor, device, class ID, and programming interface. |
| The ID's are given in hexadecimal and may be omitted or given as "*", both meaning |
| "any value". The class ID can contain "x" characters which stand for "any digit". |
| .PP |
| When |
| .B -s |
| and |
| .B -d |
| are combined, only devices that match both criteria are selected. When multiple |
| options of the same kind are specified, the rightmost one overrides the others. |
| |
| .SH OPERATIONS |
| .PP |
| There are two kinds of operations: reads and writes. To read a register, just specify |
| its name. Writes have the form |
| .IR name = value , value ...\& |
| where each |
| .I value |
| is either a hexadecimal number or an expression of type |
| .IR data : mask |
| where both |
| .I data |
| and |
| .I mask |
| are hexadecimal numbers. In the latter case, only the bits corresponding to binary |
| ones in the \fImask\fP are changed (technically, this is a read-modify-write operation). |
| |
| .PP |
| There are several ways to identify a register: |
| .IP \(bu |
| Tell its address in hexadecimal. |
| .IP \(bu |
| Spell its name. Setpci knows the names of all registers in the standard configuration |
| headers. Use `\fBsetpci --dumpregs\fP' to get the complete list. |
| See PCI bus specifications for the precise meaning of these registers or consult |
| \fBheader.h\fP or \fB/usr/include/pci/pci.h\fP for a brief sketch. |
| .IP \(bu |
| If the register is a part of a PCI capability, you can specify the name of the |
| capability to get the address of its first register. See the names starting with |
| `CAP_' or `ECAP_' in the \fB--dumpregs\fP output. |
| .IP \(bu |
| If the name of the capability is not known to \fBsetpci\fP, you can refer to it |
| by its number in the form CAP\fBid\fP or ECAP\fBid\fP, where \fBid\fP is the numeric |
| identifier of the capability in hexadecimal. |
| .IP \(bu |
| Each of the previous formats can be followed by \fB+offset\fP to add an offset |
| (a hex number) to the address. This feature can be useful for addressing of registers |
| living within a capability, or to modify parts of standard registers. |
| .IP \(bu |
| To choose how many bytes (1, 2, or 4) should be transferred, you should append a width |
| specifier \fB.B\fP, \fB.W\fP, or \fB.L\fP. The width can be omitted if you are |
| referring to a register by its name and the width of the register is well known. |
| .IP \(bu |
| Finally, if a capability exists multiple times you can choose which one to target using |
| \fB@number\fP. Indexing starts at 0. |
| |
| .PP |
| All names of registers and width specifiers are case-insensitive. |
| |
| .SH |
| EXAMPLES |
| |
| .IP COMMAND |
| asks for the word-sized command register. |
| .IP 4.w |
| is a numeric address of the same register. |
| .IP COMMAND.l |
| asks for a 32-bit word starting at the location of the command register, |
| i.e., the command and status registers together. |
| .IP VENDOR_ID+1.b |
| specifies the upper byte of the vendor ID register (remember, PCI is little-endian). |
| .IP CAP_PM+2.w |
| corresponds to the second word of the power management capability. |
| .IP ECAP108.l |
| asks for the first 32-bit word of the extended capability with ID 0x108. |
| |
| .SH SEE ALSO |
| .BR lspci (8), |
| .BR pcilib (7) |
| |
| .SH AUTHOR |